ASHRAE 90.1-2001 Section: 9.3.2 - Exterior Building Lighting Power |
||||||||||
|
Toolbox |
Requirements: The exterior building facade lighting power shall not exceed 0.25 W/ft2 of the illuminated area. The exterior lighting power allowance for all other exterior building applications is the sum of the lighting power limits permitted and specified in Table 9.3.2 for these applications. Exterior lighting for all applications (except those included in the exceptions to 9.1 and 9.3.2) shall comply with the requirements of 9.2.6. Exceptions to 9.3.2: Lighting used for the following exterior applications is exempt when equipped with an independent control device:
|
||||||||||
|
|||||||||||
|
Table 9.3.2 - Lighting Power Limits for Building Exteriors
|
|||||||||||
|