Lighting
Power Densities Using the Space-by-Space Method
|
|
|
LPD (W/ft2) |
Building
Specific Space Types
|
LPD (W/ft2) |
| Atrium-1st three
floors |
0.6 |
Automotive -
Service/Repair |
0.7 |
| Atrium-each
additional floor |
0.2 |
Bank/Office -
Banking Activity Area |
|
| Audience/Seating
Area |
0.9 |
Convention Center
- Exhibit Space |
1.3 |
| |
For Convention
Center |
0.7 |
Courthouse/Police
Station/Penitentiary |
|
| |
For Exercise
Center |
0.3 |
|
Courtroom |
1.9 |
| |
For Gymnasium |
0.4 |
|
Confinement Cells |
0.9 |
| |
For Motion Picture
Theater |
1.2 |
|
Judges Chambers |
1.3 |
| |
For Penitentiary |
0.7 |
Dormitory -
Living Quarters |
1.1 |
| |
For Performing
Arts Theater |
2.6 |
Fire Stations |
|
| |
For Religious
Buildings |
1.7 |
|
Fire Station
Engine Room |
0.8 |
| |
For Sports Arena |
0.4 |
|
Sleeping Quarters |
0.3 |
| |
For Transportation |
0.5 |
Gymnasium/Exercise Center |
|
|
Classroom/Lecture/Training |
1.4 |
|
Playing Area |
1.4 |
|
|
For Penitentiary |
1.3 |
|
Exercise Area |
0.9 |
|
Conference/Meeting/Multipurpose |
1.3 |
Hospital |
|
|
Corridor/Transition |
0.5 |
|
Emergency |
2.7 |
| |
For Hospital |
1.0 |
|
Exam/Treatment |
1.5 |
| |
For Manufacturing
Facility |
0.5 |
|
Laundry - Washing |
0.6 |
| Dining Area |
0.9 |
|
Medical Supply |
1.4 |
| |
For Penitentiary |
1.3 |
|
Nursery |
0.6 |
| |
For Hotel |
1.3 |
|
Nurse Station |
1.0 |
| |
For Motel |
1.2 |
|
Operating Room |
2.2 |
| |
For Bar
Lounge/Leisure Dining |
1.4 |
|
Patient Room |
0.7 |
| |
For Family Dining |
2.1 |
|
Pharmacy |
1.2 |
|
Dressing/Locker/Fitting Room |
0.6 |
|
Physical Therapy |
0.9 |
|
Electrical/Mechanical |
1.5 |
|
Radiology |
0.4 |
| Food Preparation |
1.2 |
|
Recovery |
0.8 |
| Laboratory |
1.4 |
Hotel/Motel Guest
Rooms |
1.1 |
| Lobby |
1.3 |
Library |
|
| |
For Hotel |
1.1 |
|
Card File &
Cataloguing |
1.1 |
| |
For Performing
Arts Theater |
3.3 |
|
Reading Area |
1.2 |
| |
For Motion Picture
Theater |
1.1 |
|
Stacks |
1.7 |
| Lounge/Recreation |
1.2 |
|
|
|
|
|
For Hospital |
0.8 |
Manufacturing |
|
| Office-Enclosed |
1.1 |
|
Low Bay (<25'
floor-to-ceiling) |
1.2 |
| Office-Open Plan |
1.1 |
|
High Bay (> 25'
floor-to-ceiling) |
1.7 |
| Restrooms |
0.9 |
|
Detailed
Manufacturing |
2.1 |
| Stairs - Active |
0.6 |
|
Equipment Room |
1.2 |
| Storage - Active |
0.8 |
|
Control Room |
0.5 |
|
|
For Hospital |
0.9 |
Museum |
|
| Storage -
Inactive |
0.3 |
|
General Exhibition |
1.0 |
|
|
For Museum |
0.8 |
|
Restoration |
1.7 |
| Workshop |
1.9 |
Parking Garage -
Parking Area |
0.2 |
|
|
Post Office -
Sorting Area |
1.2 |
| Religious
Buildings |
1.5 |
| |
Worship-pulpit,
choir |
2.4 |
| |
Fellowship Hall |
0.9 |
| Retail (For
accent lighting, see above) |
|
| |
Mall Concourse |
1.7 |
| |
Sales Area |
1.7 |
| Sports Arena |
|
| |
Court Sports Area |
2.3 |
| |
Indoor Playing
Field Area |
1.4 |
| |
Ring Sports Area |
2.7 |
|
Transportation |
|
| |
Airport -
Concourse |
0.6 |
| |
Air/Train/Bus -
Baggage Area |
1.0 |
| |
Terminal - Ticket
Counter |
1.5 |
|
Warehouse |
|
| |
Fine Material
Storage |
1.4 |
| |
Medium/Bulky
Material Storage |
0.9 |
| 1 = In cases where
both a common space type and a building specific space type are
listed, the building specific space type shall apply. |